@COMMENT This file was generated by bib2html.pl <https://sourceforge.net/projects/bib2html/> version 0.94
@COMMENT written by Patrick Riley <http://sourceforge.net/users/patstg/>
@COMMENT This file came from Hans Georg Krauthäuser's publication pages at
@COMMENT http://tu-dresden.de/et/tet
@InProceedings{Krauthaeuser05b,
  author =	 {Krauthäuser, H.~G. and Nitsch, J. and Tkachenko,
                  S. and Korovkin, N. and Scheibe, H.J.},
  booktitle =	 {Electromagnetic Compatibility, 2005. EMC 2005. 2005
                  International Symposium on},
  title =	 {Transfer impedance at high frequencies},
  year =	 2005,
  month =	 aug,
  address =	 {Chicago, USA},
  volume =	 1,
  pages =	 { 228 -- 233},
  abstract =	 { A partially new analysis method to determine the
                  transfer impedance (TI) of coaxial cables is
                  proposed. The method involves two steps. The first
                  (experimental) step consists in the determination of
                  the voltage between the interior wire and the cable
                  shield which is exposed to an exterior TEM field. In
                  the experiment the investigated cable forms a
                  semicircular loop, whose plane is orthogonal to an
                  ideally conductive plane. The measurements have been
                  performed in a GTEM cell. In the second step the
                  calculation of the TI of the cable is carried
                  out. These calculations are based on the analytical
                  solutions for the current in the cable shield. It is
                  shown that with the proposed method - in principal -
                  one can determine the complex transfer impedance for
                  frequencies up to 10 GHz for typical cable
                  diameters. Furthermore, the experimental setup is
                  rather simple compared to other methods. At the
                  moment, the evaluation of the experimental data is
                  limited to 600-700 MHz, approximately. This is due
                  to the lack of a more adequate Green's function for
                  the description of the loop in the field inside the
                  GTEM cell.},
  keywords =	 { GTEM cells; Green function; TEM field; cable
                  shield; coaxial cables; transfer impedance;
                  transverse electromagnetic cells; Green's function
                  methods; TEM cells; cable shielding; coaxial cables;
                  electromagnetic shielding;},
  doi =		 {10.1109/ISEMC.2005.1513505},
  ISSN =	 {0-7803-9380-5},
}